Features
With its small-diameter displacement meter, it can be put into spaces where measurement was previously impossible.
Single-coil structure allows for short sensor production.
The sensor and amplifier are separated and have excellent environmental resistance.
Fast 4 kHz response.
Custom orders starting from one unit accepted.
(Delivery: 6-8 weeks)
(Delivery: 6-8 weeks)
Model
WP | 20 | – | 012 | – | 02 | – | 1 |
---|---|---|---|---|---|---|---|
① | ② | ③ | ④ | ⑤ |
① | Model classification | WP | : | Wire-in Pulse Coder |
② | Sensor diameter (mm) | 20 | : | φ2 |
40 | : | φ4 | ||
50 | : | φ5 | ||
③ | Measuring range (mm) | 012 | : | 12 |
④ | Target wire diameter(mm) | 02 | : | φ0.2 |
Brass only for φ1.6 (C2700) | 03 | : | φ0.3 | |
Otherwise SUS304 | 03S | : | φ0.3(Straight type) | |
06 | : | φ0.6 | ||
10 | : | φ1.0 | ||
16 | : | φ1.6 | ||
⑤ | Amplifier | 1 | : | CV05 |
2 | : | CVS5 | 3 | : | CV06A | 4 | : | CV06D |
Specification
Model | WP20 | WP40 | ||
---|---|---|---|---|
Sensor diameter (mm) | φ2 | φ4 | ||
Target | Material | SUS304 | SUS304 | Brass(C3604) |
Outer diameter(mm) | φ0.2 | φ0.6 | φ1.6 | |
Linearity (mm) | ±2%/FS or less | 3.5%/FS or less | 3%/FS or less | |
Temperature characteristics | 2%/FS or less (0 to 60℃ @ center of measurement range) |
3%/FS or less (0 to 60℃ @ center of measurement range) |
||
Operating temperature range (℃) | -20~80℃ | |||
Lead-out cable | Length (m) | 2 (Max. 6m) | ||
Outer diameter | φ1.3 twisted pair cable | φ2.4 twisted pair cable | ||
Protective structure | equivalent to IP64 | |||
Magnetic field resistance | 0.2T(Tesla) |
Outline drawing
WP20(Standard stock item)
WP20-012
Measuring range:12㎜
WP20-030
Measuring range:30㎜
WP40
(mm) | |||
Model | B | FS | L |
---|---|---|---|
WP40-020 | 5 | 20 | 48.5 |
WP40-030 | 8 | 30 | 65 |
WP40-050 | 16.5 | 50 | 100 |
WP40-070 | 26.5 | 70 | 140 |
WP40-100 | 26.5 | 100 | 170 |
WP40-150 | 26.5 | 150 | 222 |
WP40-200 | 24.5 | 200 | 258 |
Mounting parts integrated type (Production example)
* Please let us know your preferred mounting method and shape.
WP40-050-06-R8
Amplifier
Specification
Model | CV06A | CV06D | CV05 | CVS5 CVS5(Resin case type) |
---|---|---|---|---|
Power-supply voltage | DC12~24V ±10% | DC18~24V ±10% | DC12~24V ±10% | DC9~16V ±10% |
Current consumption | 50mA or less | 100mA or less | 40mA or less | |
Output voltage | Analog output DC1~5V | |||
Resolution | Approx 1/2000 of measuring range | |||
Responsiveness | About 4kHz(-3dB) | |||
Operating temperature range | -20~80℃ (No condensation) | |||
Temperature characteristics | 0.025%/FS or less (0 to 60℃ @ center of measurement range) |
Outline drawing
CV05
CVS5
CVS5(Built-in resin case type)
(Options) CV05 sync board
Purpose
When multiple sensors of the same type are used, periodic interference noise may occur in the output.
To counter this, noise is reduced by synchronizing the signal generation circuits in each amplifier.
To counter this, noise is reduced by synchronizing the signal generation circuits in each amplifier.
Lineup
For 2 axes
For 4 axes
For 6 axes
Precautions for use
– Only connect sensors and amplifiers with the same serial numbers.
– The master amplifier is fixed.
– Slave amplifiers do not operate in isolation.
– Operation with a reduced number of slave amps connected is possible if they are the same model.
– The master amplifier is fixed.
– Slave amplifiers do not operate in isolation.
– Operation with a reduced number of slave amps connected is possible if they are the same model.
Output – power cable
Connection configuration
Standard
Cable: Dedicated 4-core cable (Length:2m)
End treatment – Amplifier side : With connector / Measuring instrument side : Unfinished
End treatment – Amplifier side : With connector / Measuring instrument side : Unfinished