TOP > Contact Linear Pulse Coder

Contact Linear Pulse Coder

CLP80-020

Features

Linear bearings are used to achieve a sliding frequency of
10 million times.
The built-in sensor is magnetic, giving it excellent environmental resistance.
Contact Linear Pulse Coder CLP80-020

Specification

Model CLP80-020
Sensor diameter (mm) φ8
Measuring range 20㎜ *Range of movement:24mm
Mechanical response About 16Hz
Force Measured Max. 1.7N (See the graph below, Force Measured – Output Characteristics [when set facing downward])
Linearity ±1.5%/FS or less
Temperature characteristics 1%/FS or less(0~60℃)
Operating temperature range(℃) -10~70
Lead-out cable Length (m) 1.5
Outer diameter Φ2.4 twisted pair shielded cable

Force Measured – Output Characteristics

Force Measured - Output Characteristics

Outline drawing

Outline drawing

Amplifier

Specification

Model CV06A CV06D CV05 CVS5
CVS5(Resin case type)
Power-supply voltage DC12~24V ±10% DC18~24V ±10% DC12~24V ±10% DC9~16V ±10%
Current consumption 50mA or less 100mA or less 40mA or less
Output voltage Analog output DC1~5V
Resolution Approx 1/2000 of measuring range
Responsiveness About 4kHz(-3dB)
Operating temperature range -20~80℃ (No condensation)
Temperature characteristics 0.025%/FS or less (0 to 60℃ @ center of measurement range)

Outline drawing

CV05
CV05
CV05
CVS5
CVS5
CVS5
CVS5(Built-in resin case type)
CVS5(Built-in resin case type)
CVS5(Built-in resin case type)

(Options) CV05 sync board

Purpose

When multiple sensors of the same type are used, periodic interference noise may occur in the output.
To counter this, noise is reduced by synchronizing the signal generation circuits in each amplifier.

Lineup

For 2 axes
For 2 axes
For 2 axes
For 4 axes
For 4 axes
For 4 axes
For 6 axes
For 6 axes
For 6 axes

Precautions for use

– Only connect sensors and amplifiers with the same serial numbers.
– The master amplifier is fixed.
– Slave amplifiers do not operate in isolation.
– Operation with a reduced number of slave amps connected is possible if they are the same model.

Output – power cable

Connection configuration

Connection configuration

Standard

Cable: Dedicated 4-core cable (Length:2m)
End treatment – Amplifier side : With connector / Measuring instrument side : Unfinished
Connection configuration

(End treatment example) * We fit a range of connectors.

(Signal side) With BNC conversion cable

(Signal side) With BNC conversion cable

(Signal side) BNC conversion cable + (Power supply side) Banana plug

 (Signal side) BNC conversion cable + (Power supply side) Banana plug

(Signal line) With Tajimi Electronics connector

 (Signal line) With Tajimi Electronics connector