TOP > Wire-in Pulse Coder – Standard

Wire-in Pulse Coder – Standard

Features

With its small-diameter displacement meter, it can be put into spaces where measurement was previously impossible.
Single-coil structure allows for short sensor production.
The sensor and amplifier are separated and have excellent environmental resistance.
Fast 4 kHz response.
Custom orders starting from one unit accepted.
(Delivery: 6-8 weeks)
Wire-in Pulse Coder - Standard

Model

WP 20 012 02 1
Model classification WP : Wire-in Pulse Coder
Sensor diameter (mm) 20 : φ2
40 : φ4
50 : φ5
Measuring range (mm) 012 : 12
Target wire diameter(mm) 02 : φ0.2
Brass only for φ1.6 (C2700) 03 : φ0.3
Otherwise SUS304 03S : φ0.3(Straight type)
06 : φ0.6
10 : φ1.0
16 : φ1.6
Amplifier 1 : CV05
2 : CVS5

Specification

Model WP20 WP40
Sensor diameter (mm) φ2 φ4
Target Material SUS304 SUS304 Brass(C3604)
Outer diameter(mm) φ0.2 φ0.6 φ1.6
Linearity (mm) ±2%/FS or less 3.5%/FS or less 3%/FS or less
Temperature characteristics 2%/FS or less
(0 to 60℃ @ center of measurement range)
3%/FS or less
(0 to 60℃ @ center of measurement range)
Operating temperature range (℃) -20~80℃
Lead-out cable Length (m) 2 (Max. 6m)
Outer diameter φ1.3 twisted pair cable φ2.4 twisted pair cable
Protective structure equivalent to IP64
Magnetic field resistance 0.2T(Tesla)

Outline drawing

WP20(Standard stock item)

WP20-012
Measuring range:12㎜
WP20
WP20-030
Measuring range:30㎜
WP20

WP40

WP40
(mm)
Model B FS L
WP40-020 5 20 48.5
WP40-030 8 30 65
WP40-050 16.5 50 100
WP40-070 26.5 70 140
WP40-100 26.5 100 170
WP40-150 26.5 150 222
WP40-200 24.5 200 258

Mounting parts integrated type (Production example)
* Please let us know your preferred mounting method and shape.

WP40-050-06-R8

WP40-050-06-R8

Converter(CV05/CVS5/Mold)

Amplifier

Specification

Model CV05 CVS5
CVS5(Resin case type)
Power-supply voltage DC12~24V ±10% DC9~16V ±10%
Current consumption 40mA or less
Output voltage Analog output DC1~5V
Resolution Approx 1/2000 of measuring range
Responsiveness About 4kHz(-3dB)
Operating temperature range -20~80℃ (No condensation)
Temperature characteristics 0.025%/FS or less (0 to 60℃ @ center of measurement range)

Outline drawing

CV05
CV05
CV05
CVS5
CVS5
CVS5
CVS5(Built-in resin case type)
CVS5(Built-in resin case type)
CVS5(Built-in resin case type)

(Options) CV05 sync board

Purpose

When multiple sensors of the same type are used, periodic interference noise may occur in the output.
To counter this, noise is reduced by synchronizing the signal generation circuits in each amplifier.

Lineup

For 2 axes
For 2 axes
For 2 axes
For 4 axes
For 4 axes
For 4 axes
For 6 axes
For 6 axes
For 6 axes

Precautions for use

– Only connect sensors and amplifiers with the same serial numbers.
– The master amplifier is fixed.
– Slave amplifiers do not operate in isolation.
– Operation with a reduced number of slave amps connected is possible if they are the same model.

Output – power cable

Connection configuration

Connection configuration

Standard

Cable: Dedicated 4-core cable (Length:2m)
End treatment – Amplifier side : With connector / Measuring instrument side : Unfinished
Connection configuration

(End treatment example) * We fit a range of connectors.

(Signal side) With BNC conversion cable

(Signal side) With BNC conversion cable

(Signal side) BNC conversion cable + (Power supply side) Banana plug

 (Signal side) BNC conversion cable + (Power supply side) Banana plug

(Signal line) With Tajimi Electronics connector

 (Signal line) With Tajimi Electronics connector

Small absolute Sensor Inquiry

    All fields malked with an asterisk* are required.

    Email address
    Company
    Department
    Official position
    Name
    Zip code
    Address
    Phone
    Inquiry ItemsMultiple selections are possible
    Detail