TOP > Wire-in Pulse Coder – L-type

Wire-in Pulse Coder – L-type

Features

With its small-diameter displacement meter, it can be put into spaces where measurement was previously impossible.
Single-coil structure allows for short sensor production.
The sensor and amplifier are separated and have excellent environmental resistance.
Fast 4 kHz response.
Custom orders starting from one unit accepted.
(Delivery: 6-8 weeks)
Wire-in Pulse Coder - L-type

Model

WL 40 090 03S 1
Model classification WL : L-type Wire-in Pulse Coder
Sensor diameter (mm) 40 : φ4
Measuring range (mm) 050 : 50
060 : 60
080 : 80
090 : 90
100 : 100
200 : 200
Target wire diameter(mm) 03 : φ0.34
03S : φ0.3(Straight Type)
Amplifier 1 : CV05
2 : CVS5

Specification

Model WL40
Sensor diameter(mm) φ4
Target Material SUS304
Outer diameter(mm) φ0.34/φ0.3 (Straight type)
Linearity(mm) 3.5%/FS or less
Temperature characteristics 3%/FS or less (15 to 25℃ @ center of measurement range) *
Operating temperature range(℃) -20~80
Lead-out cable Length(m) 2 (Max.6m)
Outer diameter φ2.4 twisted pair cable
* When using at the same humidity as the amplifier

Outline drawing

WL40-050-03S
(Measuring range:50mm)

WL40-050-03S

WL40-060-03S
(Measuring range:60mm)

WL40-060-03S

WL40-080-03
(Measuring range:80mm)

WL40-080-03

WL40-090-03/03S
(Measuring range:90㎜)

WL40-090-03/03S

WL40-100-03/03S
(Measuring range:100mm)

WL40-090-03/03S

WL40-090-03/03S [Reverse type]
(Measuring range:90mm)

WL40-090-03/03S

WL40-200-03
(Measuring range:200mm)

WL40-200-03

Converter(CV05/CVS5/Mold)

Amplifier

Specification

Model CV05 CVS5
CVS5(Resin case type)
Power-supply voltage DC12~24V ±10% DC9~16V ±10%
Current consumption 40mA or less
Output voltage Analog output DC1~5V
Resolution Approx 1/2000 of measuring range
Responsiveness About 4kHz(-3dB)
Operating temperature range -20~80℃ (No condensation)
Temperature characteristics 0.025%/FS or less (0 to 60℃ @ center of measurement range)

Outline drawing

CV05
CV05
CV05
CVS5
CVS5
CVS5
CVS5(Built-in resin case type)
CVS5(Built-in resin case type)
CVS5(Built-in resin case type)

(Options) CV05 sync board

Purpose

When multiple sensors of the same type are used, periodic interference noise may occur in the output.
To counter this, noise is reduced by synchronizing the signal generation circuits in each amplifier.

Lineup

For 2 axes
For 2 axes
For 2 axes
For 4 axes
For 4 axes
For 4 axes
For 6 axes
For 6 axes
For 6 axes

Precautions for use

– Only connect sensors and amplifiers with the same serial numbers.
– The master amplifier is fixed.
– Slave amplifiers do not operate in isolation.
– Operation with a reduced number of slave amps connected is possible if they are the same model.

Output – power cable

Connection configuration

Connection configuration

Standard

Cable: Dedicated 4-core cable (Length:2m)
End treatment – Amplifier side : With connector / Measuring instrument side : Unfinished
Connection configuration

(End treatment example) * We fit a range of connectors.

(Signal side) With BNC conversion cable

(Signal side) With BNC conversion cable

(Signal side) BNC conversion cable + (Power supply side) Banana plug

 (Signal side) BNC conversion cable + (Power supply side) Banana plug

(Signal line) With Tajimi Electronics connector

 (Signal line) With Tajimi Electronics connector

Small absolute Sensor Inquiry

    All fields malked with an asterisk* are required.

    Email address
    Company
    Department
    Official position
    Name
    Zip code
    Address
    Phone
    Inquiry ItemsMultiple selections are possible
    Detail