Features
Small contactless displacement meter
The sensor and amplifier are separated and have excellent environmental resistance.
Fast 4 kHz response. (Available up to 20 kHz)
150°C heat resistant specifications.
Custom orders starting from one unit accepted. (Delivery: 2 months)
Specification
Model | FP10-002 | |
---|---|---|
Sensor diameter (mm) | φ10 | |
Target | Material | Iron |
Temperature characteristics | 0.05%/FS or less (0 to 150℃ @ center of measuring range) | |
Operating temperature range(℃) | -20~150 | |
Lead-out cable | Length (m) | 2 (Max.6m) |
Outer diameter | φ2.3 heat resistant fluorine resin cable |
Output characteristics
Outline drawing
Installation example
Amplifier
Specification
Model | CV06A | CV06D | CV05 | CVS5 CVS5(Resin case type) |
---|---|---|---|---|
Power-supply voltage | DC12~24V ±10% | DC18~24V ±10% | DC12~24V ±10% | DC9~16V ±10% |
Current consumption | 50mA or less | 100mA or less | 40mA or less | |
Output voltage | Analog output DC1~5V | |||
Resolution | Approx 1/1000 of measuring range | |||
Responsiveness | About 4kHz(-3dB) | |||
Operating temperature range | -20~80℃ (No condensation) | |||
Temperature characteristics | 0.025%/FS or less (0 to 60℃ @ center of measurement range) |
Outline drawing
CV05
CVS5
CVS5(Built-in resin case type)
(Options) CV05 sync board
Purpose
When multiple sensors of the same type are used, periodic interference noise may occur in the output.
To counter this, noise is reduced by synchronizing the signal generation circuits in each amplifier.
To counter this, noise is reduced by synchronizing the signal generation circuits in each amplifier.
Lineup
For 2 axes
For 4 axes
For 6 axes
Precautions for use
– Only connect sensors and amplifiers with the same serial numbers.
– The master amplifier is fixed.
– Slave amplifiers do not operate in isolation.
– Operation with a reduced number of slave amps connected is possible if they are the same model.
– The master amplifier is fixed.
– Slave amplifiers do not operate in isolation.
– Operation with a reduced number of slave amps connected is possible if they are the same model.
Output – power cable
Connection configuration
Standard
Cable: Dedicated 4-core cable (Length:2m)
End treatment – Amplifier side : With connector / Measuring instrument side : Unfinished
End treatment – Amplifier side : With connector / Measuring instrument side : Unfinished